page_banner

products

TQ412 111-412-000-013 A1-B6-E050-F2-G048-H05 Proximity Transducers

short description:

Item no: TQ412 111-412-000-013 A1-B6-E050-F2-G048-H05

brand: Others

Delivery time: In Stock

Payment: T/T

shipping port: xiamen

price:$1000


Product Detail

Product Tags

Description

Manufacture Others
Model TQ412
Ordering information 111-412-000-013 A1-B6-E050-F2-G048-H05
Catalog Vibration Monitoring
Description TQ412 111-412-000-013 A1-B6-E050-F2-G048-H05 Proximity Transducers
Origin United States (US)
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

The system is based around a TQ402 or TQ412 non-contact sensor and an IQS900 signal conditioner. Together, these form a calibrated proximity measurement system in which each component is interchangeable. The system outputs a voltage or a current proportional to the distance between the transducer tip and the target, such as a machine shaft. The active part of the transducer is a coil of wire that is moulded inside the tip of the device, made of polyamide-imide. The transducer body is made of stainless steel. The target material must, in all cases, be metallic. The transducer body is available with metric or imperial thread. The TQ412 version is intended for reverse-mount applications. Both the TQ402 and TQ412 have an integral coaxial cable, terminated with a self-locking miniature coaxial connector. Various cable lengths (integral and extension) can be ordered. The IQS900 signal conditioner contains a highfrequency modulator/demodulator that supplies a driving signal to the transducer. This generates the necessary electromagnetic field used to measure the gap. The conditioner circuitry is made of high-quality components and is mounted in a painted aluminium housing.

Note: The IQS900 signal conditioner matches or betters the outstanding measurement performance and specifications of the IQS450 signal conditioner, which it replaces. Accordingly, the IQS900 is compatible with all TQ9xx and TQ4xx proximity sensors / measurement chains. In addition, the IQS900 signal conditioner includes improvements such as: SIL 2 “by design”, improved frame-voltage immunity, improved electromagnetic immunity and emissions, smaller output impedance (voltage output), optional diagnostic circuitry (that is, built-in self-test (BIST)), raw output pin, test input pin, new DIN-rail mounting adaptor and removable screw-terminal connectors for easier installation. The TQ402 and TQ412 transducers can be matched with a single EA402 extension cable to effectively lengthen the front-end. Optional housings, junction boxes and interconnection protectors are available for the mechanical and environmental protection of the connection between the integral and extension cables. TQ4xx-based proximity measurement systems can be powered by associated machinery monitoring systems such as VM600Mk2/VM600 modules (cards) , or by another power supply.

General

Transducer input requirements : High-frequency power source from an IQS900 signal conditioner Environmental Temperature ranges

• Transducer : −40 to +180°C with drift <5% (operating). +180 to +220°C with drift >5% (short-term survival).

• Transducer and cable : −40 to +195°C if used in an Ex Zone

• Cable, connector and optional protection : −40 to +200°C

Protection rating (according to IEC 60529) : The head of the proximity transducer (transducer tip and integral cable) is rated IP68

Vibration (according to IEC 60068-2-26) : 5 g peak between 10 and 500 Hz

Shock acceleration (according to IEC 60068-2-27) : 15 g peak (half sine-wave, 11 ms duration)

Physical characteristics

Transducer construction : Wire coil Ø8 mm, Torlon (polyamide-imide) tip, encapsulated in stainless steel body (AISI 316L) with high-temperature epoxy glue

Integral and extension cables : FEP covered 70 Ω coaxial cable, Ø3.6 mm

Connectors : Self-locking miniature coaxial connectors.

Note: When connecting, these should be hand-tightened until locked.

Optional protection

• Flexible stainless steel hose (protection tube) : The stainless steel hose provides additional mechanical protection but is not leak-tight

• FEP sheath (extruded fluorinated ethylene propylene) : The FEP sheath provides resistance to almost all chemicals and low permeability to liquids, gases and moisture. It is also flexible, low friction and mechanically tough.