Meggitt Vibro Meter EA403 913-403-000-012 Companies – Meggitt Vibro Meter EA402 913-402-000-012 extension cable – RuiMingSheng
Meggitt Vibro Meter EA403 913-403-000-012 Companies – Meggitt Vibro Meter EA402 913-402-000-012 extension cable – RuiMingSheng Detail:
Description
Manufacture | Meggitt Vibro Meter |
Model | extension cable |
Ordering information | EA402 913-402-000-012 |
Catalog | VM600 |
Description | Meggitt Vibro Meter EA402 913-402-000-012 extension cable |
Origin | Switzerland |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
The system is based around a TQ403 non-contact sensor and an IQS900 signal conditioner. Together, these form a calibrated proximity measurement system in which each component is interchangeable. The system outputs a voltage or a current proportional to the distance between the transducer tip and the target, such as a machine shaft.
The active part of the transducer is a coil of wire that is moulded inside the tip of the device, made of Torlon® (polyamide-imide). The transducer body is made of stainless steel. The target material must, in all cases, be metallic.
The transducer body is available only with metric thread. The TQ403 has an integral coaxial cable, terminated with a self-locking miniature coaxial connector. Various cable lengths (integral and extension) can be ordered.
The IQS900 signal conditioner contains a high-frequency modulator/demodulator that supplies a driving signal to the transducer. This generates the necessary electromagnetic field used to measure the gap. The conditioner circuitry is made of high-quality components and is mounted in a painted aluminium housing.
Note: The IQS900 signal conditioner matches or betters the outstanding measurement performance and specifications of the IQS450 signal conditioner, which it replaces. Accordingly, the IQS900 is compatible with all TQ9xx and TQ4xx proximity sensors / measurement chains.
In addition, the IQS900 signal conditioner includes improvements such as: SIL 2 “by design”, improved frame-voltage immunity, improved electromagnetic immunity and emissions, smaller output impedance (voltage output), optional diagnostic circuitry (that is, built-in self-test (BIST)), raw output pin, test input pin, new DIN-rail mounting adaptor and removable screw-terminal connectors for easier installation.
The TQ403 transducer can be matched with a single EA403 extension cable to effectively lengthen the front-end. Optional housings, junction boxes and interconnection protectors are available for the mechanical and environmental protection of the connection between the integral and extension cables.
TQ4xx-based proximity measurement systems can be powered by associated machinery monitoring systems such as VM600 cards or VibroSmart® modules, or by another power supply.
Datasheet link
Product detail pictures:
Related Product Guide:
Our development depends on the advanced equipment ,excellent talents and continuously strengthened technology forces for Meggitt Vibro Meter EA403 913-403-000-012 Companies – Meggitt Vibro Meter EA402 913-402-000-012 extension cable – RuiMingSheng , The product will supply to all over the world, such as: Poland, Slovenia, Canada, Our experience makes us important in our customer eyes. Our quality speaks itself the properties like it do not tangle, shed or breakdown, so that are our customers will always be confident while placing an order.
By Deborah from Venezuela - 2018.05.13 17:00
We have been looking for a professional and responsible supplier, and now we find it.
By Rosemary from Romania - 2017.11.11 11:41