Description

Manufacture Others
Model TFM677
Ordering information 204-677-000-003
Catalog Vibration Monitoring
Description TFM677 204-677-000-003
Origin China
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

The MPC4 machinery protection card is the central element in the machinery.
protection system (MPS). This very versatile card is capable of measuring and monitoring up to four dynamic signal inputs and up to two speed inputs simultaneously.
The dynamic signal inputs are fully programmable and can accept signals representing acceleration, velocity and displacement (proximity), among others. On-board multichannel
processing allows measurement of various physical parameters, including relative and absolute vibration, Smax, eccentricity, thrust position, absolute and differential housing
expansion, displacement and dynamic pressure.
Digital processing includes digital filtering, integration or differentiation (if required), rectification (RMS, mean value, true peak or true peak-to-peak), order tracking (amplitude and
phase) and measurement of the sensor-target gap.
The speed (tachometer) inputs accept signals from a variety of speed sensors, including systems based on proximity probes, magnetic pulse pickup sensors or TTL signals. Fractional tachometer ratios are also supported.
The configuration can be expressed in metric or imperial units. Alert and Danger set points are fully programmable, as are alarm time delay, hysteresis and latching. The Alert and Danger
levels can also be adapted as a function of the speed or any external information.
A digital output is available internally (on the corresponding IOC4T input/output card) for each alarm level. These alarm signals can drive four local relays on the IOC4T card and/or can be
routed using the rack’s Raw bus or Open Collector (OC) bus to drive relays on optional relay cards such as the RLC16 or IRC4.
The processed dynamic (vibration) signals and speed signals are available at the rear of the rack
(on the front panel of the IOC4T) as analog output signals. Voltage-based (0 to 10 V) and current-based (4 to 20 mA) signals are provided.