MA133 809-133-000-011 Mounting Adaptors Kit
Description
Manufacture | Others |
Model | MA133 |
Ordering information | 809-133-000-011 |
Catalog | Vibration Monitoring |
Description | MA133 809-133-000-011 Mounting Adaptors Kit |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
MA133 is a Mounting adapter kit for CA20x and CE31x, with Micaver® (mica-glass) thermally isolating base. Refer to product drawing 809-133-000V011.
General
Input power requirements : None
Signal transmission : 2-pin system, insulated from case, charge output
Signal processing : Charge converter (IPC70x signal conditioner)
Operating (At 23°C ±5°C, 73°F ±9°F)
Sensitivity (at 120 Hz with 5 g, see Calibration on page 4) : 100 pC/g ±5%
Dynamic measurement range : 0.01 to 400 g peak
Overload capacity (spikes) : Up to 500 g peak
Linearity • 0.01 to 20 g (peak) : ±1% • 20 to 400 g (peak) : ±2%
Transverse sensitivity : ≤3% Resonant frequency : >22 kHz nominal
Frequency response
• 0.5 to 6000 Hz : ±5% (lower cutoff frequency is determined by the signal conditioner)
• Typical deviation at 8 kHz : +10% Internal insulation resistance : 109 Ω minimum Capacitance (nominal)
• Sensor : 5000 pF pin to pin. 10 pF pin to case (ground).
• Cable (per metre of cable) : 105 pF/m pin to pin. 210 pF/m pin to case (ground). Environmental Temperature range
• Continuous operation : −55 to +260°C (−67 to +500°F) for sensor. −55 to +200°C (−67 to +392°F) for integral cable.
• Short-term survival : −70 to +280°C (−94 to +536°F) for sensor. −62 to +250°C (−80 to +482°F) for integral cable.
Temperature sensitivity error (with respect to 23°C, 73°F)
• −55 to +23°C (−67 to +73°F) : 0.25%/°C
• +23 to 260°C (−73 to +500°F) : 0.1%/°C Corrosion, humidity
• Sensor : Austenitic stainless-steel (1.4441), hermetically welded
• Protection hose : Heat-resistant stainless-steel (1.4541), hermetically welded