EC318 922-318-000-002/5000 Cable Assemblies
Description
Manufacture | Others |
Model | EC318 |
Ordering information | 922-318-000-002/5000 |
Catalog | Vibration Monitoring |
Description | EC318 922-318-000-002/5000 Cable Assemblies |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
Operating
Sensitivity
• 0 to 10 g versions (ordering option code B010) : 4 to 20 mA proportional to 0 to 10 g RMS ±5%
• 0 to 20 g versions (ordering option code B020) : 4 to 20 mA proportional to 0 to 20 g RMS ±5%
Note: 4 mA corresponds to no vibration, 20 mA to full scale.
Transverse sensitivity : <5% Linearity : ±1% maximum
Frequency response : 3 to 10000 Hz (±10%)
Resonant frequency : 21 kHz nominal
Electrical
Power supply voltage (for current loop) : 10 to 30 VDC.
Note: 4 to 20 mA current loop voltage between pins A+ and B−.
Maximum loop resistance (RMAX) : RMAX = ( Power supply voltage − 10 V ) / 20 mA
Grounding : Isolated from case (machine ground)
Internal isolation (case to shield) : 100 MΩ minimum
Reverse polarity : Protected
Overvoltage : Protected
Environmental
Temperature range : −55 to 90°C (−67 to 194°F).
Note: −55 to 120°C (−67 to 248°F) with max. loop current of 10 mA.
Humidity : IP68 (according to IEC 60529)
Shock vibration limit : 2500 g peak
Continuous vibration limit : 500 g peak
Approvals
Conformity : European Union (EU) declaration of conformity (CE marking)
Electromagnetic compatibility (EMC) : EMC compliant (2014/30/EU). EN 61326-1.