Assume full obligation to meet all demands of our customers; accomplish ongoing advancements by promoting the advancement of our customers; become the final permanent cooperative partner of clientele and maximize the interests of shoppers for DO810-EA 3BSE008510R2 , RLM01 3BDZ000398R1 , Abb Ai895 3bsc690086r1 , Quality is factory' life , Focus on customer' demand is the source of company survival and development, We adhere to honesty and good faith working attitude, looking forward to your coming !
Best MRU311DM Company - Woodward 5464-836 Remote Xcvr Module – RuiMingSheng Detail:

Description

Manufacture Woodward
Model 5464-836
Ordering information 5464-836
Catalog MicroNet Digital Control
Description Woodward 5464-836 Remote Xcvr Module
Origin United States (US)
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

A Smart I/O module has its own on-board microcontrollers. The modules described in this chapter are Smart I/O modules. During initialization of a smart module, the module’s microcontroller turns the
LED off after power-on self-tests have passed and the CPU has initialized the module. The LED is illuminated to indicate an I/O fault.

The CPU also tells this module in which rate group each channel is to run, as well as any special information (such as the type of thermocouple in the case of a thermocouple module). At run time, the CPU then periodically broadcasts a “key” to all I/O cards, telling them which rate groups are to be updated at that time.

Through this initialization/key broadcast system, each I/O module handles its own rate-group scheduling with minimal CPU intervention. These smart I/O modules also have on-card on-line fault detection and automatic calibration/compensation. Each input channel has its own precision voltage
reference. Once per minute, while not reading inputs, the on-board microcontroller reads this reference. The microcontroller then uses this data read from the voltage reference for both fault detection and automatic temperature compensation/calibration.

Limits have been set for the expected readings when the on-board microcontroller reads each voltage reference. If the reading obtained is outside these limits, the system determines that the input channel, A/D converter, or the channel’s precision-voltage reference is not functioning properly. If this happens,
the microcontroller flags that channel as having a fault condition. The CPU will then take whatever action the application engineer has provided for in the application program.

A smart output module monitors the output voltage or current of each channel and alerts the system if a fault is detected. Each I/O module has a fuse on it. This fuse is visible and can be changed through a cutout in the plastic cover of the module. If the fuse is blown, replace it with a fuse of the same type and size.

Figure 10-3 is a block diagram of the two-channel actuator controller module. Each channel controls an integrating or proportional, hydromechanical or pneumatic actuator. Each actuator may have up to two position feedback devices. There are several versions available, and the module part number indicates the module’s maximum output current capability. A MicroNet lowdensity discrete (gray) cable must be used with this module. Do not use an analog (black) cable.

This Actuator Driver module receives digital information from the CPU and generates four proportional actuator-driver signals. These signals are proportional and their maximum range is 0 to 25 mAdc or 0 to 200 mAdc.

Figure 10-5 is a block diagram of the four-channel Actuator Driver module. The system writes output values to dual-port memory through the VME-bus interface. The microcontroller scales the values using calibration constants stored in EEPROM, and schedules outputs to occur at the proper time. The microcontroller monitors the output voltage and current of each channel and alerts the system of any channel and load faults. The system can individually disable the current drivers. If a fault is detected which prevents the module from operating, by either the microcontroller or the system, the FAULT LED will illuminate.


Datasheet link


Product detail pictures:

Best MRU311DM Company - Woodward 5464-836 Remote Xcvr Module – RuiMingSheng detail pictures


Related Product Guide:

We always get the job done being a tangible workforce making sure that we can easily give you the very best quality as well as finest selling price for Best MRU311DM Company - Woodward 5464-836 Remote Xcvr Module – RuiMingSheng , The product will supply to all over the world, such as: San Diego, Monaco, Honduras, We will supply much better products with diversified designs and professional services. We sincerely welcome friends from over the world to visit our company and cooperate with us on the basis of long-term and mutual benefits.
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Griselda from New Zealand - 2017.08.16 13:39
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Polly from Italy - 2018.09.21 11:01

    Send your message to us: