Sticking towards the theory of "Super Good quality, Satisfactory service" ,We are striving to become a superb business enterprise partner of you for Abb Ldmui-01 61320946c , Invensys Triconex 3700A , Abb Sdcs-Con-2 3adt309600r1 , We, with open arms, invite all interested buyers to visit our website or contact us directly for further information.
Best Invensys Triconex 3503E Companies – ABB CI625-E2 3BHT300038R1 Modules – RuiMingSheng Detail:

Description

Manufacture ABB
Model CI625-E2
Ordering information 3BHT300038R1
Catalog 800xA
Description ABB CI625-E2 3BHT300038R1 Modules
Origin Germany (DE)
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

Compatibility with MasterBus 90
The MasterPiece 90 must be updated with the Advant Controller 110 system software.
A MasterPiece 90 may be connected to the Advant Fieldbus 100 through a CI625 module.

MasterBus 90 and Advant Fieldbus 100 are slave compatible. The CI625 must not be a bus administrator on the Advant Fieldbus 100. The bus administrator functionality is disabled by resetting the MASTER terminal on the CI625 DB element in the MasterPiece 90.
It is not supported to use Advant Fieldbus 100 equipment on the MasterBus 90. If a MasterBus 90 is to be extended with Advant Fieldbus 100 equipment, it has to be converted to Advant Fieldbus 100.
DataSet Peripherals can not be configured on the CI625 but it is possible to configure up to 100 DataSets on the module. DataSets can also be configured to the CI626 in an Advant Controller 110, but not on the CI520/CI522 in an Advant Controller 400 Series or the on CI525/CI526/CI527 in the AdvaSoft for Windows and AC 100 OPC Server.

In the Advant Controller 400 Series, DataSets can not be defined for the Advant Fieldbus 100.

Redundant line error detection is not used in the slave functionality on the CI625. Therefore, an Advant Fieldbus 100 that uses CI625s must have one AF 100 communication interface placed at each end of the bus for full redundant line error detection.


Datasheet link


Product detail pictures:

Best Invensys Triconex 3503E Companies –  ABB CI625-E2 3BHT300038R1 Modules – RuiMingSheng detail pictures


Related Product Guide:

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Best Invensys Triconex 3503E Companies – ABB CI625-E2 3BHT300038R1 Modules – RuiMingSheng , The product will supply to all over the world, such as: Australia, Iceland, London, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our goods, make sure you contact us now. We're looking forward to hearing from you soon.
  • The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Madeline from Zambia - 2017.08.28 16:02
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By King from New Zealand - 2017.12.31 14:53

    Send your message to us: