Best Bently Nevada 3500/65-01-00 145988-02 - Bently Nevada 3500/61-01-00 133819-02 RTD/TC Non-Isolated I/O Module Internal Terminations – RuiMingSheng
Best Bently Nevada 3500/65-01-00 145988-02 - Bently Nevada 3500/61-01-00 133819-02 RTD/TC Non-Isolated I/O Module Internal Terminations – RuiMingSheng Detail:
Description
Manufacture | Bently Nevada |
Model | 3500/61-01-00 |
Ordering information | 133819-02 |
Catalog | 3500 |
Description | Bently Nevada 3500/61-01-00 133819-02 RTD/TC Non-Isolated I/O Module Internal Terminations |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
Description
The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.
The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.
When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.
Ordering Information
For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com.
Recorder Outputs
3500/61-AA-BB
A:I/O Module Type
0 1 RTD/TC Non-isolated I/O Module Internal Terminations
0 2 RTD/TC Non-isolated I/O Module External Terminations
0 3 TC Isolated I/O Module Internal Terminations
0 4 TC Isolated I/O Module External Terminations
0 5 RTD/TC Non-isolated I/O Module with Internal Barriers
B:Agency Approval Option
0 0 None
0 1 CSA/NRTL/C (Class 1, Div 2)
0 2 ATEX/ IECEx/ CSA (Class 1, Zone 2)
3500/61 -Specific
163179-02 3500/61 Temperature Monitor (with recorders)
133819-02 3500/61 RTD/TC Non-Isolated I/O Module Internal Terminations.
133827-02 3500/61 RTD/TC Non-Isolated I/O Module External Terminations.
133835-02 3500/61 TC Isolated I/O Module Internal Terminations.
133843-02 3500/61 TC Isolated I/O Module External Terminations.
133892-01 3500/61 Recorder Output External Termination Block (Terminal Strip connectors).
133900-01 3500/61 Recorder Output External Termination Block (Euro Style connectors).
136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations. (Not-Isolated)
Datasheet link
Product detail pictures:
Related Product Guide:
With a positive and progressive attitude to customer's curiosity, our organization repeatedly improves our products top quality to meet the wants of consumers and further focuses on safety, reliability, environmental necessities, and innovation of Best Bently Nevada 3500/65-01-00 145988-02 - Bently Nevada 3500/61-01-00 133819-02 RTD/TC Non-Isolated I/O Module Internal Terminations – RuiMingSheng , The product will supply to all over the world, such as: United Kingdom, New Zealand, Brasilia, What You Need Is What We Pursue.We are sure our products will bring you first class quality.And now sincerely hope to promote partner friendship with you from all over the world. Let's joint hands to cooperate with mutual benefits!
By Gloria from Belize - 2018.11.04 10:32
Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
By Carol from Dominica - 2017.10.27 12:12