page_banner

products

Best 9905-969 Supplier - Woodward 1720-015 31902-02 4-314871-1 accessories – RuiMingSheng

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our advancement depends on the superior gear ,superb talents and consistently strengthened technology forces for Triconex 3008 Main Processor , ABB TB840A 3BSE037760R1 , Abb Do810-Ea 3bse008510r2 , Since establishment within the early 1990s, now we have arrange our sale network in USA, Germany, Asia, and several Middle Eastern countries. We intention to get a top class supplier for worldwide OEM and aftermarket!
Best 9905-969 Supplier - Woodward 1720-015 31902-02 4-314871-1 accessories – RuiMingSheng Detail:

Description

Manufacture Woodward
Model 1720-015 31902-02 4-314871-1
Ordering information 1720-015 31902-02 4-314871-1
Catalog MicroNet Digital Control
Description Woodward 1720-015 31902-02 4-314871-1 accessories
Origin United States (US)
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

A Smart I/O module has its own on-board microcontrollers. The modules described in this chapter are Smart I/O modules. During initialization of a smart module, the module’s microcontroller turns the
LED off after power-on self-tests have passed and the CPU has initialized the module. The LED is illuminated to indicate an I/O fault.

The CPU also tells this module in which rate group each channel is to run, as well as any special information (such as the type of thermocouple in the case of a thermocouple module). At run time, the CPU then periodically broadcasts a “key” to all I/O cards, telling them which rate groups are to be updated at that time.

Through this initialization/key broadcast system, each I/O module handles its own rate-group scheduling with minimal CPU intervention. These smart I/O modules also have on-card on-line fault detection and automatic calibration/compensation. Each input channel has its own precision voltage
reference. Once per minute, while not reading inputs, the on-board microcontroller reads this reference. The microcontroller then uses this data read from the voltage reference for both fault detection and automatic temperature compensation/calibration.

Limits have been set for the expected readings when the on-board microcontroller reads each voltage reference. If the reading obtained is outside these limits, the system determines that the input channel, A/D converter, or the channel’s precision-voltage reference is not functioning properly. If this happens,
the microcontroller flags that channel as having a fault condition. The CPU will then take whatever action the application engineer has provided for in the application program.

A smart output module monitors the output voltage or current of each channel and alerts the system if a fault is detected. Each I/O module has a fuse on it. This fuse is visible and can be changed through a cutout in the plastic cover of the module. If the fuse is blown, replace it with a fuse of the same type and size.

Figure 10-3 is a block diagram of the two-channel actuator controller module. Each channel controls an integrating or proportional, hydromechanical or pneumatic actuator. Each actuator may have up to two position feedback devices. There are several versions available, and the module part number indicates the module’s maximum output current capability. A MicroNet lowdensity discrete (gray) cable must be used with this module. Do not use an analog (black) cable.

This Actuator Driver module receives digital information from the CPU and generates four proportional actuator-driver signals. These signals are proportional and their maximum range is 0 to 25 mAdc or 0 to 200 mAdc.

Figure 10-5 is a block diagram of the four-channel Actuator Driver module. The system writes output values to dual-port memory through the VME-bus interface. The microcontroller scales the values using calibration constants stored in EEPROM, and schedules outputs to occur at the proper time. The microcontroller monitors the output voltage and current of each channel and alerts the system of any channel and load faults. The system can individually disable the current drivers. If a fault is detected which prevents the module from operating, by either the microcontroller or the system, the FAULT LED will illuminate.


Datasheet link


Product detail pictures:

Best 9905-969 Supplier - Woodward 1720-015 31902-02 4-314871-1 accessories – RuiMingSheng detail pictures


Related Product Guide:

The customer satisfaction is our primary target. We uphold a consistent level of professionalism, quality, credibility and service for Best 9905-969 Supplier - Woodward 1720-015 31902-02 4-314871-1 accessories – RuiMingSheng , The product will supply to all over the world, such as: Thailand, USA, Lisbon, Our staffs are adhering to the "Integrity-based and Interactive Development" spirit, and the tenet of "First-class Quality with Excellent Service". According to the needs of every customer, we provide customized & personalized services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By John biddlestone from Zimbabwe - 2017.09.16 13:44
    We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Karen from San Diego - 2018.06.28 19:27

    Send your message to us: