Best 330910-05-09-10-01-CN - Bently Nevada 3500/60-01-00 133819-01 RTD/TC non-Isolated I/O Module, Internal Terminations – RuiMingSheng
Best 330910-05-09-10-01-CN - Bently Nevada 3500/60-01-00 133819-01 RTD/TC non-Isolated I/O Module, Internal Terminations – RuiMingSheng Detail:
Description
Manufacture | Bently Nevada |
Model | 3500/60-01-00 |
Ordering information | 133819-01 |
Catalog | 3500 |
Description | Bently Nevada 3500/60-01-00 133819-01 RTD/TC non-Isolated I/O Module, Internal Terminations |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
Description
The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.
The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.
When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.
Ordering Information
For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com.
Without Recorder Outputs
3500/60-AA-BB
A:I/O Module Type
0 1 RTD/TC Non-isolated I/O Module Internal Terminations
0 2 RTD/TC Non-isolated I/O Module External Terminations
0 3 TC Isolated I/O Module Internal Terminations
0 4 TC Isolated I/O Module External Terminations
0 5 RTD/TC Non-isolated I/O Module with Internal Barriers
B:Agency Approval Option
0 0 None
0 1 CSA/NRTL/C (Class 1, Div 2)
0 2 ATEX/ IECEx/ CSA (Class 1, Zone 2)
3500/60 -Specific
163179-01 3500/60 Temperature Monitor (without recorders)
133827-01 3500/60 RTD/TC Non-Isolated I/O Module, External Terminations.
133819-01 3500/60 RTD/TC non-Isolated I/O Module, Internal Terminations
133835-01 3500/60 TC Isolated I/O Module, Internal Terminations.
133843-01 3500/60 TC Isolated I/O Module, External Terminations.
136711-01 3500/60 RTD/TC I/O Module with Internal Barriers and Internal Terminations. (Not-Isolated)
Datasheet link
Product detail pictures:
Related Product Guide:
No matter new customer or outdated client, We believe in extensive phrase and trusted relationship for Best 330910-05-09-10-01-CN - Bently Nevada 3500/60-01-00 133819-01 RTD/TC non-Isolated I/O Module, Internal Terminations – RuiMingSheng , The product will supply to all over the world, such as: Peru, Indonesia, Greece, In order to meet the increasing requirement of customers both home and aboard, we will keep carrying forward the enterprise spirit of "Quality, Creativity, Efficiency and Credit" and strive to top the current trend and lead fashion. We warmly welcome you to visit our company and make cooperation.
By Jenny from Greek - 2017.03.07 13:42
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
By Christine from Istanbul - 2018.09.19 18:37