Bently Nevada 3300/55 Dual Velocity Monitor
Description
Manufacture | Bently Nevada |
Model | 3300/55 |
Ordering information | 3300/55 |
Catalog | 3300 |
Description | Bently Nevada 3300/55 Dual Velocity Monitor |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
Details
Description
The 3300/55 Dual Velocity Monitor provides two channels of continuous on-line machinery vibration monitoring. The monitor accepts inputs from one or two Velomitor® transducers, High Temperature Velomitor Systems (HTVS), or Velocity Seismoprobe® transducers without the need for interface modules. Flexibility is designed into the Dual Velocity Monitor. Many user-selectable options, such as high- and low-pass filter corner frequency options, can be easily (re)programmed in the field with plug-in jumpers
Dual Velocity Monitor 3300/55-AXX-BXX-CXX-DXX-EXX-FXX-GXX-HXX Factory-set Option Descriptions
A: Channel Input Option 0 1 Dual Velocity Inputs: Channels A & B indicate in peak velocity. 0 2 Dual Velocity Inputs: Channel A indicates in peak velocity units, Channel B indicates in peak-to-peak displacement. 0 3 Dual Velocity Inputs: Channels A & B indicate in peak-to-peak displacement. 0 4 Dual Velocity Inputs: Channels A & B indicate in rms velocity. 0 5 Single Velocity Input: Channels A & B indicate in peak velocity. 0 6 Single Velocity Input: Channel A indicates in peak velocity units, Channel B indicates in peak-to-peak displacement. 0 7 Single Velocity Input: Channels A & B indicate in peak-to-peak displacement. 0 8 Single Velocity Input: Channels A & B indicate in rms velocity.
B: Transducer Type Option 0 1 9200 or 74712, 500 mV/in/s (2- wire, 10 kΩ input impedance). 0 2 47633 or 86205, 500 mV/in/s (2-wire, 24.9 kΩ input impedance) 0 3 145 mV/in/s (CEC 4-126) 0 4 Velomitor 100 mV/in/s 0 5 HTVS 145 mV/in/s Note: The transducer voltage must be selected for 24 Vdc in the power supply when the Velomitor or HTVS option is used.
C: Channel A Full-scale Range Option 0 1 0 - 0.5 in/s pk 0 2 0 - 1 in/s pk
0 3 0 - 2 in/s pk 0 4 0 - 5 mils pp 0 5 0 - 10 mils pp 0 6 0 - 20 mils pp 0 7 0 - 0.5 in/s rms 0 8 0 - 1 in/s rms 0 9 0 - 2 in/s rms 1 1 0 - 10 mm/s pk 1 2 0 - 20 mm/s pk 1 3 0 - 50 mm/s pk 1 4 0 - 100 µm pp 1 5 0 - 200 µm pp 1 6 0 - 500 µm pp 1 7 0 - 10 mm/s rms 1 8 0 - 20 mm/s rms 1 9 0 - 50 mm/s rms
D: Channel B Full-scale Range Option 0 1 0 - 0.5 in/s pk 0 2 0 - 1 in/s pk 0 3 0 - 2 in/s pk 0 4 0 - 5 mils pp 0 5 0 - 10 mils pp 0 6 0 - 20 mils pp 0 7 0 - 0.5 in/s rms 0 8 0 - 1 in/s rms 0 9 0 - 2 in/s rms 1 1 0 - 10 mm/s pk 1 2 0 - 20 mm/s pk 1 3 0 - 50 mm/s pk 1 4 0 - 100 µm pp 1 5 0 - 200 µm pp 1 6 0 - 500 µm pp 1 7 0 - 10 mm/s rms 1 8 0 - 20 mm/s rms 1 9 0 - 50 mm/s rms
E: Agency Approval Option 0 0 Not Required 0 1 CSA/NRTL/C 0 2 ATEX self certification Note: ATEX approval requires the monitor rack be installed in a weatherproof housing.
F: Intrinsic Safety Barriers 0 0 None 0 1 External (01, 02, 03 Transducer types) 0 2 Internal (01, 02, 03 Transducer types) 0 3 External (04, 05 Transducer types) Notes: External Safety Barriers must be ordered separately.